Calibrating pressure transmitters, gauges, and switches out in remote plant areas, offshore platforms, or onboard vessels gets slow fast when you have to haul nitrogen cylinders or run extension cords. The SIKA P60 pneumatic hand test pump generates -0.95 bar vacuum up to +60 bar positive pressure from ambient air alone, which makes it a solid workhorse for field instrumentation teams.
Step-by-Step Field Setup

Before pumping, give the O-rings on both the reference gauge port and the flexible test hose a quick visual check. Mount your digital or analog reference manometer on top of the pump body and connect the device under test through the pressure hose. Make sure the release valve is snugged shut before you start rough pumping.
Switching Modes and Dialing Fine Pressure
You can switch between vacuum (-0.95 bar) and positive pressure (+60 bar) using the built-in changeover valve without grabbing extra tools. After rough pressurization with the scissor handles, the fine-adjustment volume valve lets you dial in millibar-level steps smoothly against the reference display.
Managing Temperature Drift and Leak Checks
Tip from the field: When compressing air up to 40-60 bar, slight heating happens inside the hose and chamber, so the gauge usually drifts down for 20 to 30 seconds as it cools. Wait for things to settle before logging points; if pressure keeps dropping steadily, check hose fittings and Teflon seals for leaks.
Choosing the Right Process Connection
Field devices use a mix of G1/4 BSP, 1/4 NPT, 1/2 NPT, and metric threads. Always confirm the thread standard on both the reference manometer and the unit under test before heading out to site so seals seat cleanly without cross-threading.
Pump-Only vs. Complete Kit: A Buyer's Note
SIKA sells the P60 as a bare pump (OEM/Pump-Only) for labs that already keep hoses and adapters on hand, and as a Complete Kit with a hard carrying case, chrome-plated brass adapter set, pressure hose, and Teflon seal kit. For field maintenance crews working across mixed plant gear, ordering the Complete Kit saves you from getting stuck mid-job over one missing fitting.